General Specifications

OUTPUTS
Relay: Two form “C “ relays rated at 3A @ 30 Vac or Vdc. Each programmable for control, obstacle, alarm or shunt.
Sounder: Programmable for key presses and relay activation.
Voice: Synthesized human voice prompts for visitor and programming assistance. Voice is heard through speaker and remote telephones.
INPUTS
Call Button: push button input used to initiate communications
RF: integral 318 MHz super heterodyne receiver @ -100dBm sensitivity (typical); receives Linear block coded transmitters and MGT supervised safety edge transmitters
Open Request : terminal input for each relay; when activated, will trigger the assigned relay for the programmed relay on time
Door Sense/Inhibit: terminal input for each relay monitors status of a protected entry point or can be programmed to restrict access to the assigned relay
Keypad: 12 digit telephone style keypad for accepting entry codes and for local programming
Power: 16 Vac (transformer included); input for externally charged 12 to 24 Vdc battery backup
Current Draw (dialing out to one phone): 16 Vac: 270 mA standby
440 mA operating
12 Vdc: 250 mA standby
500 mA operating
24 Vdc 150 mA standby
300 mA operating
Operating Temperature : -22°F to 149°F (-30°C to 65°C)
PROGRAMMING
Programming: Locally via keypad; remotely via touchtone telephone phone or computer with modem running a web browser. NO SOFTWARE REQUIRED
Memory: All data memory is stored in non volatile EEPROM with data retention in excess of 10 years
Clock/Calendar: 24/7 clock/calendar with battery backup used for time zones; relay hold open times; date/time stamp for event log entries; downlight on/off times
Connections: All power, telephone, relay and control connections to the unit are with plug on screw terminal blocks; RJ-45 and BNC connections for optional RE-BWC
camera kit
STANDARD EQUIPMENT
RE-1: RE-1: Residential telephone entry system that is capable of sharing an existing phone line, a dedicated line and dialing out up to 3 additional off site numbers or used in as an intercom; integral keypad used to accept entry codes; integral radio receiver will accept signals from block coded transmitters; built-in clock calendar; voice prompts; accepts one remote keypad; provisions for dealer installed (not included) Knox switch; telephone bypass switch
AVAILABLE ACCESSORIES
RE-BWC: field upgradeable black & white CCTV camera; camera includes infrared illuminators for clear picture in low / no light conditions; receives power from RE-1
AM-KP: auxiliary wired keypad used for accepting entry codes to control a second door or gate
Block Coded Transmitters: adding remotes is easy thanks to the RE-1’s integral radio receiver